KNOWLEDGE BASE ARTICLE

Embedding on Sharp OSA Devices

In order for shortcuts to the Umango App to be automatically added to a Sharp device when assigning it as a source, the Umango OSA app must be configured on the device.

To do this, follow the steps below.

  1. In a browser, open the device's web panel
  2. Login (if necessary)
  3. From the panel's menu; choose System Settings >> Sharp OSA Settings >> Standard Application Settings. (For models prior to CR4: choose Applications >> External Applications Settings >> Standard Application Settings)
  4. At the bottom of the table, click the Add button, which will load a form.
  5. Enter in the following Details in to the form
  6. Name = Umango
  7. Address = http://{SERVERIP}:{PORT}/mfd/init where {SERVERIP} is the return IP address of the machine that Umango is running on; and where {PORT} is, 55580 for Umango Extract or 55080 for Umango Convert
  8. Extended Platform is Checked
  9. Then save the form.

Link to this article http://umango.com/KB?article=87